Event
Event Name
Number
(DEC/hex)
Not Ready
86/0x56
Manual
Intervention
Required
Data loss
87/0x57
detected
Format
88/0x58
Precluded due
to LUN
Existence
Can't
89/0x59
download
because NV is
not shutdown
Event
Predictive
Logged
Maintenance
Implication
N
Ignore
Y
NA
N
NA
N
NA
Event Code Descriptions
Suspected
Description
Components
None
The disk array is not ready
and the action required to
solve the problem will
require user intervention.
Check system state
information for more
details.
None
An otherwise successful read
op failed due to data loss
recorded in at least 1 of the
disk blocks read.
None
The subsystem could not be
formatted because logical
units were created and still in
existence. Delete all LUNs
prior to issuing the format
subsystem command.
None
Download is not possible even
though the target controller is
in NO CODE because the
NVRAM image is not valid on
the disks (i.e., the subsystem is
not shutdown). Make the
secondary controller the
primary controller, have it
shutdown and then do the
download.