HP Surestore Disk Array 12h - And FC60 Service Manual page 173

Hp surestore e disk array 12h user's and service manual (c5445-90901, september 1999)
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Event
Event Name
Number
(DEC/hex)
RAM Image
187/0xbb
Upload Failed
Old Cache
188/0xbc
Configuration
Used
Incompatible
189/0xbd
RAM Image
Content
Internal SCSI
190/0xbe
Underrun
Event
Event
Predictive
Logged
Maintenance
Implication
Y
Single
Occurrence
Ignore - See
Y
errors
associated with
shutdown
Y
Ignore -
Operator error
Y
Single
Occurrence not
accompanied
by other errors
Event Code Descriptions
Suspected
Description
Components
Disk Drives
The controller was unable to
upload a usable disk copy of
Controller
NVRAM during startup. This
Internal SCSI
may be a result of missing or
Bus
failing disk drives.
None
Write data found in the
uploaded NVRAM image
blocked a requested transition
to a new cache configuration.
The previous configuration is
being used.
None
The current RAM
configuration is not
compatible with the RAM
configuration of the NVRAM
disk image. This is caused by
a different mapping of
NVRAM in the disk image
that cannot be supported by
the current configuration. For
example, the disk image may
support 8 GB disk drives but
the current configuration does
not.
To use the existing disk
image, the current controller
map configuration must be
changed to match the disk
map configuration.
Disk Drive
A disk drive sent/received less
data than expected.
Controller
Internal SCSI
Bus
Troubleshooting
173

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore e disk array 12h

Table of Contents