Troubleshooting
Event Code Descriptions
Event
Event Name
Number
(DEC/hex)
Pass Through
42/0x2a
Reset Failed
Recovered With
43/0x2b
RAID 1
Redundancy
Unavailable
44/0x2c
Data Detected
By RAID 1
Shutdown
45/0x2d
Failed
Disk Drive
47/0x2f
Removed
During Add
Physical Drive
144
Event
Predictive
Logged
Maintenance
Implication
Y
Ignore
Ignore - See
Y
Accompanying
Errors
Ignore - See
Y
accompanying
errors
NA
N
N
NA
Suspected
Description
Components
None
A command to the disk drive
failed. Drive status should be
returned and can be examined
to determine the condition of
the disk drive.
None
Redundancy was used by the
controller in the successful
completion of a read or write.
None
The controller detected that
the disk drives necessary for a
read or write were not
available for access before the
access was attempted. This
can apply to an initial attempt
to read or write, or to a retry.
None
The controller could not
shutdown the disk array
because all the disk drives
were missing. Reinstall the
missing disks to shutdown the
array.
None
A disk drive was removed
from the disk array while an
Add Physical Drive command
was in progress against the
drive.

Advertisement