HP Surestore Disk Array 12h - And FC60 Service Manual page 125

Hp surestore e disk array 12h user's and service manual (c5445-90901, september 1999)
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Error Message
System States:
An invalid configuration has been detected,
Disk Warning
caused by one of the following cases:
Case 1) a failed disk module in the array
Case 2) a Previously-Used disk module has
been added
Case 3) a "down" disk drive in system
System States:
A fan in slot F1, F2, or F3 failed.
Fan Failed
(or)
Fan Missing
System States:
The controller event/fault logs are full.
Log Full
System States:
A disk that is required is no longer present.
Missing Disk
System States:
NVRAM errors have occurred.
NVRAM Failed
System States:
A power module has failed.
Power Supply
Failed
System States:
The RAM is not being reflected in both
RAM
controllers due to some other error condition.
Unmirrored
System States:
The rebuild process terminated abnormally.
Rebuild Failed
System States:
A Hot Pluggable operation has occurred.
Verifying Disks
System States:
A warning condition exists on the disk array.
Warning
Explanation
Control Panel Error Messages
Action
The following action should be performed for
each of the cases listed:
Case 1) Replace the disk module and perform a
Rebuild.
Case 2) Use Include Disk on the Previously-
Used disk module or remove the Previously-
Used disk module.
Case 3) Fix or replace the disk drive.
Check the fan status lights to determine which
fan module failed, then replace the fan module.
CAUTION: Do not remove a fan module
until a replacement fan is available. Also,
replace only one fan at a time. Removing two
fans at one time shuts down the power
module!
Use a SCSI command to clear the logs.
(You may want to read the logs first.)
Find the missing disk to recover data.
Check the control panel display for more
information regarding what to replace.
Replace the indicated power module.
Determine what the other error condition is by
the front panel.
Restart the rebuild or add more capacity.
None. Information only.
Check the front panel for appropriate action to
identify and correct the problem.
Troubleshooting
125