Troubleshooting
Control Panel Error Messages
Error Message
Not Enough
There are not enough (fewer than three) disk
Disks
modules in a logical drive set for redundancy.
The NVRAM images miscompared; array
NVRAM
doesn't know which image to use. This error can
Mismatch
occur if you remove two controllers from two
separate arrays, neither of which were
Shutdown, and install them into a new array.
Caution: The data memory maps stored in
NVRAM are necessary to read the user data.
NVRAM x/y
The NVRAM in the controller module in slot X
Failed
or Y failed.
Offline SCSI ID
One or more controller in this disk array has not
been assigned a SCSI ID.
Optimizing
The array is migrating data to RAID 0/1 to
optimize the array performance.
Power Off
The primary array controller attempted to switch
Failure
off the power to the power module but it was
unsuccessful.
Power Off
The disk array will continue to function if one
Pending
fan module fails; however, when a fan module is
physically removed from the disk array
enclosure, this disrupts the flow of cooling air to
the other modules in the enclosure.
Power 1 Failed
The power module in slot P1 failed.
Power 2 Failed
The power module in slot P2 failed.
Power 3 Failed
The power module in slot P3 failed.
130
Explanation
Action
Install more disk modules.
If possible:
1) remove both controllers,
2) reinstall them in their original arrays,
3) run Shutdown,
4) return them to the array where the error
occurred, or;
1) remove one controller,
2) power on the array and wait for it to become
"Ready,"
3) Shutdown the array,
4) reinstall the controller you removed,
5) power on the disk array.
Replace the controller.
Set the desired SCSI ID for the controller(s).
None. Information only.
Either the secondary array controller or the
primary array controller failed and did not
allow the power off to occur, or the power
module itself may be malfunctioning.
If you remove a fan module (whether it is
working or has failed) from the disk array
enclosure, it must be replaced in ten minutes or
less, or a power-off will occur.
Replace power module P1.
Replace power module P2.
Replace power module P3.