Troubleshooting
Event Code Descriptions
Event
Event Name
Number
(DEC/hex)
Secondary
213/0xd5
Controller
Failed, Entered
Isolation Mode
Secondary
214/0xd6
Controller
Failed, Entered
Separation
Mode
180
Event
Predictive
Logged
Maintenance
Implication
Y
Ignore if
corrected by
power cycle
Y
Ignore if
corrected by
reset or power
cycle
Suspected
Description
Components
Controller
A controller was discovered to
Backplane
be bad during power on.
Specifically, the secondary
controller appears to have
failed due to an event which
caused isolation mode to be
entered. In isolation mode
controller X becomes the
primary controller and
controller Y is offline.
This may be recovered by
power cycle.
Controller
A controller was discovered to
Backplane
be bad during power on.
Specifically, the secondary
controller appears to have
failed due to an event which
caused separation mode to be
entered. In separation mode,
the NVRAM contents is not
mirrored between controllers.
This may be recovered by
reset or power cycle.