HP Surestore Disk Array 12h - And FC60 Service Manual page 140

Hp surestore e disk array 12h user's and service manual (c5445-90901, september 1999)
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Troubleshooting
Event Code Descriptions
Event
Event Name
Number
(DEC/hex)
Recovered By
22/0x16
Disk Drive
Disk Drive
23/0x17
Media Error
Disk Drive
24/0x18
Hardware Error
Disk Drive
25/0x19
Reset By
Related Hot
Plug
Disk Drive
26/0x1a
Reset Itself
140
Event
Predictive
Logged
Maintenance
Implication
Y
See
information
provided by
drive vendor
See
Y
information
provided by
disk drive
vendor
See
Y
information
provided by
drive vendor
N
NA
NA
N
Suspected
Description
Components
Disk Drive
Data was recovered be the
disk drive using its own
internal recovery process. The
sense information provided by
the disk drive should provide
more information on the
nature of the failure.
Disk Drive
The disk drive returned a
status indicating a media error
condition. Retries have been
exhausted. This event will
only occur in degraded mode.
Disk Drive
The disk drive returned a
status indicating a hardware
error condition. The
controller retries are
exhausted, or the I/O is not
retryable. This event will only
occur in degraded mode.
None
A disk drive sharing the same
internal bus as the target drive
was either installed or
removed causing a bus reset.
The controller could not retry
the I/O either because it is not
retryable (RAID 5), or retries
are exhausted.
None
The disk drive returned a
status indicating it had been
reset. The controller could not
retry this I/O. The host should
retry the I/O.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore e disk array 12h

Table of Contents