Troubleshooting
Event Code Descriptions
Event
Event Name
Number
(DEC/hex)
Disk Drive Data
32/0x20
Transfer Failed
Disk Drive
33/0x21
Miscompare on
Write And
Verify
Disk Drive State
34/0x22
Conflict
Disk Drive Data
35/0x23
Out Of Sync
After Access
142
Event
Predictive
Logged
Maintenance
Implication
N
NA
Single
Y
Occurrence
Ignore
Y
Y
Ignore - See
accompanying
errors
Suspected
Description
Components
None
The I/O completed with status
indicating the data transfer
failed. All retries are
exhausted or the I/O is not
retryable.
The read verify following a
Disk Drive
write indicated a Miscompare
Controller
error status. All retries are
Internal SCSI
exhausted or the I/O is not
Bus
retryable.
None
A disk drive was in the wrong
state for read, write or pass
through. For a read or write,
the wrong states are "down",
"missing", or "initialization
failed". For pass through, the
wrong state is "missing".
Check the state of the disk
drive and try to return it to
"ready" by adding it if it was
downed, or reinstalled it if it is
missing.
None
Data being read or written to a
disk drive was out of sync
after the access was complete.
The redundant copy of the
data stored on the disk drive is
no longer valid. A rebuild will
ensure the data is valid.