11. Verify if the primary controller currently installed has the desired firmware using the front panel
display. The following table shows the proper front panel commands to view which controller is the
primary array controller, and what version of firmware is on the primary array controller.
KEY
CANCEL CANCEL
MENU
ENTER
+
+
+
+
+
12. Copy the firmware from the primary controller to the secondary controller using the front panel:
KEY
CANCEL CANCEL
MENU
+
ENTER
ENTER
ENTER
13. The front panel display should say "Not Enough Disks". Check the "System State" on the front panel
display. It should say "Not Enough Disks" with no other warnings.
KEY
CANCEL CANCEL
MENU
ENTER
+
HP SureStore E Disk Array 12H Controller
DISPLAY
"Not Enough Disks"
"Language"
"View Settings"
"System State: Not Enough Disks"
"Warning: Firmware Needed"
"Primary Cntrl: X"
"SCSI ID x: __"
"SCSI ID y: __"
"Firmware: HP__"
DISPLAY
"Not Enough Disks"
"Language"
"Cntrl Changes"
"SCSI ID"
"Copy Firmware"
"Confirm"
"Copying Firmware",
then "Firmware Loading",
then array will initialize
then "Not Enough Disks"
DISPLAY
"Not Enough Disks"
"Language"
"View Settings"
"System State: Not Enough Disks"
"Primary Cntrl: X"
Firmware Download Procedure