Event
Event Name
Number
(DEC/hex)
Cache Version
221/0xdd
Mismatch In
RAM Image
RAM Version
222/0xde
Mismatch
Event
Predictive
Logged
Maintenance
Implication
Y
See errors
associated with
shutdown
Y
NA
Event Code Descriptions
Suspected
Description
Components
None
A new version of controller
firmware has been download
with writes stuck in cache.
Normally there will be no
writes stuck in cache and a
firmware download will
complete without any
problems. However, if there
are writes stuck in cache, the
upload will fail with this event
code.
To correct this it may be
necessary to revert to the old
version of firmware and solve
whatever problem is causing
writes to be stuck in cache
(probably one or more disks
have failed).
None
The upload routine was unable
to upload part of the disk
NVRAM image because the
current firmware does not
support that use of RAM.
(Most likely an older version
of firmware is trying to upload
a disk image posted by some
other firmware version.)
Troubleshooting
183
Need help?
Do you have a question about the Surestore Disk Array 12h - And FC60 and is the answer not in the manual?
Questions and answers