Event
Event Name
Number
(DEC/hex)
Local Controller
228/0xe4
Failed DRAM
Address Decode
Test
Remote
229/0xe5
Controller
Failed DRAM
Address Decode
Test
Controller
230/0xe6
Failed
Background
ROM checksum
test
Scrub policy
231/0xe7
detected error
Event
Predictive
Logged
Maintenance
Implication
Y
Ignore if
recovered by
reset or power
on
Y
Ignore if
recovered by
reset or power
on
Y
Ignore if
recovered by
reset or power
on
Y
Ignore - should
be preceded by
Drive errors
Event Code Descriptions
Suspected
Description
Components
DRAM SIMM,
This error code indicates that
Controller
the DRAM SIMM on the local
controller failed the DRAM
address decode test during the
power-on process.
Specifically, the DRAM
SIMM on the primary
controller failed the decode
test.
DRAM SIMM,
This error code indicates that
Controller
the DRAM SIMM on the
remote controller failed the
DRAM address decode test
during the power-on process.
Specifically, the DRAM
SIMM on the secondary
controller failed the decode
test.
ROM,
This error code indicates that
Controller
the ROM on the local
controller failed the ROM
checksum test done in the
background during idle time.
The firmware stored in the
ROM is corrupted.
Disk drive
This error code indicates that
an error was returned to the
Scrub policy by a device read.
It is logged to provide
information about the cause of
the error. Additional
information about the error
from the device should
precede this entry.
Troubleshooting