Event
Event Name
Number
(DEC/hex)
No Disk Drives
135/0x87
Found During
Initialization
Insufficient
136/0x88
Space During
Rebuild
Rebuild Started
137/0x89
Rebuild
138/0x8a
Complete
Insufficient
139/0x8b
Space To Start
Rebuild
Rebuild Failed
140/0x8c
Event
Predictive
Logged
Maintenance
Implication
Y
Ignore -
Operator
activity
Ignore - See
Y
accompanying
errors.
Ignore - See
Y
accompanying
errors.
Ignore
Y
Y
Ignore - See
accompanying
errors
Y
Ignore - See
accompanying
errors
Event Code Descriptions
Suspected
Description
Components
None
During startup no disk drives
were present. A new disk set
was created with no members.
None
There is insufficient disk
space for migrating data
during a rebuild. This is a
controller error, although the
disk array may still support
some I/Os without adding
disks.
None
A rebuild has been started
either automatically or by
command.
None
A rebuild has completed
successfully.
None
A rebuild was not started due
to insufficient disk space. This
event is most likely to occur
when Active Hot Spare is not
enabled.
To create the necessary disk
space, add a disk or delete a
LUN.
None
Rebuild has failed to complete
due to multiple disk failures or
a controller failure. Previous
messages in the log should
indicate whether or not there
have been multiple disk
failures.
Troubleshooting