Event
Event Name
Number
(DEC/hex)
Cancel Rebuild
48/0x30
With Auto-
Rebuild Enabled
Disk Drive
49/0x31
Stamp Write
Failed
Event
Predictive
Logged
Maintenance
Implication
N
NA
Y
Single
Occurrence -
See
accompanying
errors
Event Code Descriptions
Suspected
Description
Components
None
An attempt was made to
cancel a rebuild operation
while Auto-Rebuild was
enabled. Because Auto-
Rebuild is enabled, the rebuild
would only start up again after
the cancel, rendering it
ineffective. Therefore the
controller always rejects a
cancel rebuild command while
Auto-Rebuild is enabled.
Disk Drive
In order to make a disk drive a
member of a disk set it must
Controller
have a stamp written onto it by
Internal SCSI
the controller. This error
Bus
indicates that the writing or
updating of the stamp failed
during an Add Physical Drive
command, causing the
command to fail.
This is typically caused by
disk drive errors.