Troubleshooting
Event Code Descriptions
Event
Event Name
Number
(DEC/hex)
Logical Unit
149/0x95
Deleted
Logical Unit
150/0x96
Renumbered
Disk Set
151/0x97
Attached
Unable To
152/0x98
Complete
Internal Data
Transfer
164
Event
Predictive
Logged
Maintenance
Implication
Y
Ignore -
operator or
host activity
Ignore - host
Y
activity
Y
Ignore -
operator
activity
Y
Ignore - See
accompanying
errors
Suspected
Description
Components
None
The controller has
successfully deleted a LUN.
The number of the deleted
LUN appears in the last 8
bytes of the component
identifier field of this log
entry.
None
The controller has
successfully renumbered a
LUN. The component
identifier field of this log entry
contains the original number
of the LUN (first 8 bytes) and
the new number of the LUN
(last 8 bytes).
None
The controller has
successfully attached to a new
disk set. This occurs after
every format disk array, and
whenever a power on or reset
occurs while the controller is
not attached to a disk set. In
some cases, the currently
attached disk set may be
empty.
None
The system experienced a
memory error and was unable
to resolve the error because
DMAs did not complete. The
disk drive must be reset.