Event
Event Name
Number
(DEC/hex)
Multiple
93/0x5d
Failures
Suspected
During
Recovery
Volume Set
94/0x5e
Missing
During
Recovery
RAM
95/0x5f
Configuration
Mismatch
During
Recovery
Event
Predictive
Logged
Maintenance
Implication
Y
- see
Ignore
accompanyin
g errors
Y
Ignore -
operator error
Y
Single
Occurrence
Event Code Descriptions
Suspected
Description
Components
None
Conditions detected during
recovery indicate that at least
one failure or hot plug
occurred in addition to the loss
of NVRAM that the recovery.
This implies that data integrity
likely to have been
compromised in ways that are
detectable outside of the
occurrence of this log or sense
data report. It is likely that the
controller does not have
sufficient information to
determine the extent of the
damage.
None
The volume set referenced in a
recover command is not
present in the subsystem. If a
NULL volume set was
referenced then this error
indicates that no members of
any volume set were present.
This error can also result from
incompatible stamp versions.
Controller
An attempt was made to
recover an image after RAM
SIMM,
loss but the image would not
operator error
fit in the non-failing memory
available on the controller.
Either the SIMM
configuration has been
modified, or one or more
SIMMs have failed. Recovery
may be possible using another
controller as the primary
controller.
Troubleshooting
155
Need help?
Do you have a question about the Surestore Disk Array 12h - And FC60 and is the answer not in the manual?