Troubleshooting
Event Code Descriptions
Event
Event Name
Number
(DEC/hex)
Cancel Rebuild
183/0xb7
Started
Rebuild IO
184/0xb8
Priority
Changed
Non-Member
185/0xb9
Drive Removed
Drive Missing
186/0xba
At Power On
172
Event
Predictive
Logged
Maintenance
Implication
Y
Ignore -
Operator or
Host activity
Y
Ignore - Host
activity
Y
Ignore -
Operator
activity
Y
Ignore unless
no Operator
activity
Suspected
Description
Components
None
A rebuild has been canceled
either automatically or by
command. The disk array
automatically cancels a
rebuild if it needs to restart
rebuild due to a disk addition,
a LUN deletion, or a LUN
format.
None
The host has changed the
rebuild priority.
None
The controller detected that a
disk drive was removed. This
event occurs for drives that are
not disk set members when
they are removed. The device
number field is not used.
Disk Drive
Indicates that a disk drive was
discovered to be missing
Controller
during a power on or reset.
Internal SCSI
This event occurs for disk set
Bus
members only.
The disk drive ID number
assigned to the missing drive
appears in the component
identifier field of this log
entry. A disk drive ID number
consisting of the controller
serial number followed by a 0
indicates that the disk drive ID
number has not yet been
assigned.