For Release 4.0 or later, you can use any terminal emulation software to configure the 1600 DSL
module, including Hyperterminal that is packaged with Windows. For a local serial port connection,
the terminal emulator must be configured as follows:
Data Bits–8
I
Stop Bits–1
I
Parity–None
I
Flow Control–None
I
Speed–19,200 bps
I
To configure the 1600 DSL module, you must know the voice gateway that is used on the remote
end and program the following:
SDSL interface
I
Voice gateway configuration
I
Router configuration for voice (PathStar only)
I
Router configuration for data
I
LAN configuration
I
For any changes you make to take effect, you must perform a cold start on the system by
powering down and powering up the system, or by using the Restore Programming
(#125) or System Reset–Programming Saved (#728) feature.
For more information about voice and data configuration of the 1600 DSL module, see the
®
PARTNER
ACS 1600 DSL Module manual.
SDSL Interface Configuration
Follow these steps to configure the SDSL interface for a 1600 DSL module:
1. Select "5. Configure WAN" from the Main Menu.
2. Select "1. SDSL" at the Available WAN Interfaces prompt.
3. Select "0. Quick Configuration" from the WAN Configuration Menu.
4. Select the appropriate Digital Subscriber Line Access Multiplexer (DSLAM) from the Quick
Configuration menu.
The 1600 DSL module automatically resets. After five minutes if the LED above the SDSL port
on the 1600 DSL module is a steady green, go to Step 8. If after five minutes the LED is
flashing or not on at all, proceed with Step 5.
5. Select "2. Configure Physical Interface" from the WAN Configuration Menu.