Identifying SNMP Trap Messages
Component Name (Oracle ILOM CLI
Targets)
/SYS/DBP/HDD[0-x]/STATE
/SYS/DBP/HDD[0-x]/SERVICE
/SYS/DBP/HDD[0-x]/OK2RM
/SYS/DBP/HDD[0-x]/NVME
/SYS/DBP/HDD[0-x]/NVME/PRSNT
Related Information
"System Chassis Components" on page 291
■
"Cooling Unit Components" on page 293
■
"Disk Backplane Components" on page 294
■
"Memory Device Components" on page 295
■
"Power Unit Components" on page 295
■
"Processor Components" on page 297
■
"System Motherboard Components" on page 297
■
"System Firmware Components" on page 299
■
Identifying SNMP Trap Messages
It is possible to configure Oracle ILOM to generate Simple Network Management Protocol
(SNMP) traps when hardware problems occur. For information about how to configure SNMP
300
Oracle Server X8-2L Service Manual • January 2021
IPMI Type
Description
Discrete sensor Writable multistate, slot/connector
sensor type, per IPMI
Indicator
Hard disk drive Fault-Service
Required LED
Indicator
Hard disk drive OK to Remove LED
FRU
NVMe drive FRU
Discrete sensor NVMe device presence
Values (if applicable)
01h-FAULT_STATUS
02h-IDENTITY
04h-INSTALLED
20h-SLOT_POWER_OFF
Color: Amber
Location: HDD
Off: Normal
On: Hard disk drive was diagnosed
as faulty.
Color: Blue
Location: HDD
Off: Normal
On: Drive is ready to remove.
01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
Need help?