Power Events
Messages and Descriptions
Severity and Description: Informational; A power supply sensor has reported that its value has
gone below an upper fatal threshold setting or above a lower fatal threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
SNMP Trap: sunHwTrapSensorCritThresholdExceeded
Oracle ILOM Event Message: Lower critical threshold exceeded
Severity and Description: Major; A power supply sensor has reported that its value has gone
above an upper critical threshold setting or below a lower critical threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
SNMP Trap: sunHwTrapSensorCritThresholdDeasserted
Oracle ILOM Event Message: Lower critical threshold no longer exceeded
Severity and Description: Informational; A power supply sensor has reported that its value has
gone below an upper critical threshold setting or above a lower critical threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
SNMP Trap: sunHwTrapVoltageFatalThresholdExceeded
Oracle ILOM Event Message: Lower fatal threshold exceeded
Severity and Description: Critical; A voltage sensor has reported that its value has gone above
an upper fatal threshold setting or below a lower fatal threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
SNMP Trap: sunHwTrapVoltageFatalThresholdDeasserted
Oracle ILOM Event Message: Lower fatal threshold no longer exceeded
Severity and Description: Informational; A voltage sensor has reported that its value has gone
below an upper fatal threshold setting or above a lower fatal threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
SNMP Trap: sunHwTrapVoltageCritThresholdExceeded
Oracle ILOM Event Message: Upper critical threshold exceeded
Severity and Description: Critical; A voltage sensor has reported that its value has gone above
an upper critical threshold setting or below a lower critical threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
SNMP Trap: sunHwTrapVoltageCritThresholdDeasserted
Oracle ILOM Event Message: Upper critical threshold no longer exceeded
306
Oracle Server X8-2L Service Manual • January 2021
Component Name
/SYS/PS[0-1]/P_IN
/SYS/PS[0-1]/P_OUT
/SYS/PS[0-1]/P_IN
/SYS/PS[0-1]/P_OUT
/SYS/PS[0-1]/V_12V
/SYS/PS[0-1]/V_12V_STBY
/SYS/PS[0-1]/V_IN
/SYS/PS[0-1]/V_12V
/SYS/PS[0-1]/V_12V_STBY
/SYS/PS[0-1]/V_IN
/SYS/PS[0-1]/V_12V
/SYS/PS[0-1]/V_12V_STBY
/SYS/PS[0-1]/V_IN
/SYS/PS[0-1]/V_12V
/SYS/PS[0-1]/V_12V_STBY