Oracle X8-2L Service Manual page 305

Table of Contents

Advertisement

Messages and Descriptions
SNMP Trap: sunHwTrapPowerSupplyOk
Oracle ILOM Event Message: PS_CONFIG_ERROR DEASSERT
Severity and Description: Major; A power supply sensor has detected an error.
SNMP Trap: sunHwTrapSensorNonCritThresholdExceeded
Oracle ILOM Event Message: Upper noncritical threshold exceeded
Severity and Description: Minor; A sensor has reported that its value has gone above an upper
non critical threshold setting or below a lower non critical threshold setting. This generic 'sensor'
trap is generated when the SNMP agent does not recognize the component type.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
SNMP Trap: sunHwTrapSensorThresholdOk
Oracle ILOM Event Message:Upper noncritical threshold no longer exceeded
Severity and Description: Informational; A sensor has reported that its value is in the normal
operating range. This generic 'sensor' trap is generated when the SNMP agent does not recognize
the component type.
SNMP Trap: sunHwTrapSensorNonCritThresholdExceeded
Oracle ILOM Event Message: Upper noncritical threshold exceeded
Severity and Description: Minor; A sensor has reported that its value has gone above an upper
noncritical threshold setting or below a lower noncritical threshold setting. This generic 'sensor'
trap is generated when the SNMP agent does not recognize the component type.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
SNMP Trap: sunHwTrapSensorThresholdOk
Oracle ILOM Event Message: Upper noncritical threshold no longer exceeded
Severity and Description: Informational; A sensor has reported that its value is in the normal
operating range. This generic 'sensor' trap is generated when the SNMP agent does not recognize
the component type.
SNMP Trap: sunHwTrapSensorFatalThresholdExceeded
Oracle ILOM Event Message: Lower fatal threshold exceeded
Severity and Description: Critical; A power supply sensor has reported that its value has gone
above an upper fatal threshold setting or below a lower fatal threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
SNMP Trap: sunHwTrapSensorFatalThresholdDeasserted
Oracle ILOM Event Message: Lower fatal threshold no longer exceeded
Component Name
/SYS/PS[0-1]/STATE
/SYS/VPS
/SYS/VPS
/SYS/VPS_FANS
/SYS/PS[0-1]/P_IN
/SYS/PS[0-1]/P_OUT
/SYS/VPS_FANS
/SYS/PS[0-1]/P_IN
/SYS/PS[0-1]/P_OUT
/SYS/PS[0-1]/P_IN
/SYS/PS[0-1]/P_OUT
/SYS/PS[0-1]/P_IN
/SYS/PS[0-1]/P_OUT
Monitoring Components and Identifying SNMP Messages
Power Events
305

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the X8-2L and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents