Verify NVMe Cable Connections
NVME drives pcie link check:
Checking NVME drive DSN...
NVME drives DSN check:
Checking NVME cabling...
NVME cable check:
NVME test PASSED
diag>
If any of the tests fail, there could be a problem with the cabling. For example:
If a cable is crossed (plugged into the incorrect port), then the NVMe drive DSN (Drive
■
Serial Number) test should report two drives where the DSN does not match. The cabling
for those drives should be inspected to ensure that it is correct.
If multiple NVMe drive PCIe links are not active, or multiple NVMe drive DSNs are not
■
OK, then check the Port 2 connection on the NVMe switch card. If Port 2 is incorrectly
cabled, it could affect all three drives that are connected to that NVMe switch card.
Once issues are resolved, power cycle the system by removing the power cords
7.
from the power supplies, waiting 30 seconds, and then reattaching the power
cords.
8.
Retest the system by repeating
Once all NVMe cable connection tests have passed, the server operating system can be booted.
202
Oracle Server X8-2L Service Manual • January 2021
checking pcie link on drive NVMe 11
checking DSN on drive NVMe 0
checking DSN on drive NVMe 1
checking DSN on drive NVMe 2
checking DSN on drive NVMe 3
checking DSN on drive NVMe 4
checking DSN on drive NVMe 5
checking DSN on drive NVMe 6
checking DSN on drive NVMe 7
checking DSN on drive NVMe 8
checking DSN on drive NVMe 9
checking DSN on drive NVMe 10
checking DSN on drive NVMe 11
Cables associated with Switch Card 0 in PCIe Slot 3 verified
Cables associated with Switch Card 1 in PCIe Slot 4 verified
Cables associated with Switch Card 2 in PCIe Slot 8 verified
Cables associated with Switch Card 3 in PCIe Slot 9 verified
OK
PASSED
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
PASSED
PASSED
Step 1
through
Step
6.
Need help?
Do you have a question about the X8-2L and is the answer not in the manual?
Questions and answers