Messages and Descriptions
SNMP Trap: sunHwTrapSlotOrConnectorError
Oracle ILOM Event Message: Assert
Severity and Description: Major: A sensor associated with a slot or connector has detected an error.
SNMP Trap: sunHwTrapSlotOrConnectorOk
Oracle ILOM Event Message: Deassert
Severity and Description: Informational; A sensor associated with a slot or connector has returned
to its normal state.
Related Information
"System Chassis Components" on page 291
■
"Cooling Unit Components" on page 293
■
"Disk Backplane Components" on page 294
■
"Memory Device Components" on page 295
■
"Power Unit Components" on page 295
■
"Processor Components" on page 297
■
"System Motherboard Components" on page 297
■
"Hard Disk Drive Components" on page 299
■
Power Events
The following table lists power events.
Messages and Descriptions
SNMP Trap: sunHwTrapPowerSupplyError
Oracle ILOM Event Message: PS_PRESENCE ASSERT
Severity and Description: Major; A power supply sensor has detected an error.
SNMP Trap: sunHwTrapPowerSupplyOk
Oracle ILOM Event Message: PS_PRESENCE DEASSERT
Severity and Description: Major; A power supply sensor has detected an error.
SNMP Trap: sunHwTrapPowerSupplyError
Oracle ILOM Event Message: PS_FAILURE ASSERT
Component Name
/SYS/PS[0-1]/STATE
/SYS/PS[0-1]/STATE
/SYS/PS[0-1]/STATE
Monitoring Components and Identifying SNMP Messages
Power Events
Component Name
/SYS/DBP/HDD[0-x]/STATE
/SYS/DBP/HDD[0-x]/STATE