21. Check that lift cylinder lock-out valves (A) are open.
22. Start tractor and fully raise header.
23. Shut down tractor and remove key from ignition.
24. Close both lift cylinder lock-out valves (A).
25. At left side of carrier, install tensioner bolt (B)
into spring.
26. Turn in both float spring tensioner bolts (B) to achieve
the following exposed thread (C) measurements:
• 5-11/16–6-1/8 in. (145–155 mm) for 13-foot.
• 3-3/4–4-1/8 in. (95–105 mm) for 16-foot.
27. Replace the driveshields.
Driveshields, page
93.
28. If endwise transport system is installed, reconnect
electrical harness (A) to the lights (B) and secure
harness to shielding using existing clips (C) and (D).
29. Secure harness to light bracket with plastic tie
wraps (E).
169821
CHANGING THE CONDITIONER
Refer to
7.2 Closing
90
Figure 6.33: Lift Cylinder Lock-Out Valve
Figure 6.34: Right Side Shown – Left
Side Similar
Figure 6.35: Electrical Harness
Revision D