8.9 Checking Forward and Rear Swivel Gearbox Lubricant
There are two swivel gearboxes located on the mower conditioner. The swivel gearbox consists of an upper and
lower gearbox. Check plugs are located at the same position on each gearbox and need to be removed in
order to check the lubricant level.
IMPORTANT:
Check the swivel gearbox lubricant level when the lubricant is warm. If the lubricant is cold, idle the machine for
approximately 10 minutes prior to checking.
DANGER
To avoid bodily injury or death from unexpected startup of the machine, always stop the engine and remove
the key from the ignition before leaving the operator's seat for any reason.
Figure 8.14: Forward and Rear Swivel Gearboxes
A - Upper Forward Gearbox
169821
PERFORMING PREDELIVERY CHECKS
B - Lower Forward Gearbox
C - Upper Rear Gearbox
107
D - Lower Rear Gearbox
Revision D