Got Data Backup And Reinstallation; Backup Procedures - Mitsubishi Electric C70 Setup Manual

Hide thumbs Also See for C70:
Table of Contents

Advertisement

MITSUBISHI CNC
10 Data Backup and Restoration

10.1 GOT Data Backup and Reinstallation

Standard functions (standard monitor OS), communication driver, BootOS and projects in GOT can be backed up in
batch to the CF card inserted in GOT.
The data backed up in batch can be reinstalled to GOT in easy operation.
(Note 1) See below for the procedure when OS data and project data (drawing data) are stored in "C Drive". If OS data
and project data (drawing data) are installed in "A Drive (CF card)", backup data from the CF card.
(Note 2) When using GOT1000 series GT16, USB memory is also available for backup and reinstallation.
.

10.1.1 Backup procedures

(1) Set "OFF" the CF Card access switch.
(2) Insert the CF Card into the card slot.
(3) Set "ON" the CF Card access switch.
(4) Open the GOT Utility screen.
For GT15: Press the right and left top corners together.
For GT16: Press the left top corner.
154
OFF
ON
CF card
ON
OFF