【#21158(PR)】 SC_EQP_4 Safety device mounting information 4
Set the devices' mount status when the device manufacturer's safety sequence is shared by
machines with different safety device configurations.
Each bit's data is copied to M840 - M847 respectively at every power ON, which may be used in the
device manufacturer's safety sequence on both NC-side and PLC-side.
Each bit corresponds to the following device No.
bit0: M840
bit1: M841
bit2: M842
bit3: M843
bit4: M844
bit5: M845
bit6: M846
bit7: M847
---Setting range---
00000000 to 11111111
【#21159(PR)】 SC_EQP_CHK3 Safety device mounting information check 3
Use this parameter to prevent the incorrect setting of "#21157 SC_EQP_3 (Safety device mounting
information 3)".
Set the same value as in "#21157 SC_EQP_3 (Safety device mounting information 3)".
Each bit's data is copied to M848 - M855 respectively at the power ON.
Each bit corresponds to the following device No.
bit0: M848
bit1: M849
bit2: M850
bit3: M851
bit4: M852
bit5: M853
bit6: M854
bit7: M855
---Setting range---
00000000 to 11111111
【#21160(PR)】 SC_EQP_CHK4 Safety device mounting information check 4
Use this parameter to prevent the incorrect setting of "#21158 SC_EQP_4 (Safety device mounting
information 4)".
Set the same value as in "#21158 SC_EQP_4 (Safety device mounting information 4)".
Each bit's data is copied to M856 - M863 respectively at the power ON.
Each bit corresponds to the following device No.
bit0: M856
bit1: M857
bit2: M858
bit3: M859
bit4: M860
bit5: M861
bit6: M862
bit7: M863
---Setting range---
00000000 to 11111111
【#21161(PR)】 SftySgnl ChkTrg Dual signal check-time change
Set this parameter to change the dual signal module's output ON/OFF check time and the contactor
welding detection start time after the power ON.
0: Automatically start checking after the power ON
1: Start checking at the rising edge of the "Dual signal check start (G+001/Y311)" signal.
(Note) Setting "1" is allowed only when the power supply to I/Os is impossible at the controller's
power ON.
Appendix 1.3 Base Specifications Parameters