Mitsubishi Electric C70 Setup Manual page 260

Hide thumbs Also See for C70:
Table of Contents

Advertisement

【#2073】 zrn_dog Origin dog Random assignment device
Set the input device in this parameter to assign the origin dog signal.
(Note 1) This parameter is valid when "1" is set in "#1226 aux10/bit5".
(Note 2) When this parameter is valid, do not set the existing device number. If the existing device
---Setting range---
0000 to 02FF (HEX)
【#2074】 H/W_OT+ H/W OT+ Random assignment device
Set the input device in this parameter to assign the OT (+) signal.
(Note 1) This parameter is valid when "1" is set in "#1226 aux10/bit5".
(Note 2) When this parameter is valid, do not set the existing device number. If the existing device
---Setting range---
0000 to 02FF (HEX)
【#2075】 H/W_OT- H/W OT- Random assignment device
Set the input device in this parameter to assign the OT (-) signal.
(Note 1) This parameter is valid when "1" is set in "#1226 aux10/bit5".
(Note 2) When this parameter is valid, do not set the existing device number. If the existing device
---Setting range---
0000 to 02FF (HEX)
【#2076】 index_x
Not used. Set to "0".
【#2077】 G0inps G0 in-position width
Set the in-position width for G0.
Between SV024 and this parameter, the parameter with a larger value will be applied.
When "0" is set, this parameter will be invalid: only SV024 will be available.
---Setting range---
0.000 to 99.999 (mm)
【#2078】 G1inps G1 in-position width
Set the in-position width for G1.
Between SV024 and this parameter, the parameter with a larger value will be applied.
When "0" is set, this parameter will be invalid: only SV024 will be available.
---Setting range---
0.000 to 99.999 (mm)
【#2079(PR)】 chcomp Chopping compensation coefficient
Set the coefficient to be applied to the compensation amount for the insufficient amount caused by
servo delay during chopping.
---Setting range---
0 to 10 (standard value: 8)
number is set, an emergency stop will occur. However, no device number check will be
performed for an axis to which the "near-point dog ignored" signal is input.
number is set, an emergency stop will occur. However, no device number check will be
performed for an axis to which the "OT ignored" signal is input.
number is set, an emergency stop will occur. However, no device number check will be
performed for an axis to which the "OT ignored" signal is input.
Appendix 1.4 Axis Specifications Parameters