(6) On the [MULTI CPU PARAM.] screen, set the following values.
(Note) Refer to Chapter 5 when connecting more than one CNC CPU.
Setting up CPU#1 (PLC CPU)
-CPU specific send range #26701 = 3
-auto refresh area size
-Restricted system area
-Unsynchronize CPU boot-up #26704 = 0
Setting up CPU#2 (CNC CPU)
-CPU specific send range #26711 = 3
-auto refresh area size
-Restricted system area
-Unsynchronize CPU boot-up #26714 = 0
-#26741 Command Slot No. = 0
-#26742 G Device TOP number = 10000
MULTI CPU PARAM.
DATA
EMG EMERGENCY M01 OPERATION ERROR
BASE
(7) Turn the power OFF and ON.
(Note)
The parameter settings won't be enabled unless the power is turned ON again.
#26702 = 0
#26703 = 1
#26712 = 0
#26713 = 1
AXIS
SERVO
C70 Setup Manual
4.3 Setting Multi-CPU Parameters
SETUP PARAM
MULTI
MENU
85