Mitsubishi Electric C70 Setup Manual page 295

Hide thumbs Also See for C70:
Table of Contents

Advertisement

MITSUBISHI CNC
Appendix 1 Explanation of Parameters
【#2313】 SV113 SSF8 Servo function 8
Select the servo functions.
A function is assigned to each bit.
Set this in hexadecimal format.
bit F : ssc SLS (Safely Limited Speed) function
0: Stop
bit E-9 :
Not used. Set to "0".
bit 8 : sto Dedicated wiring STO function
Set this parameter to use dedicated wiring STO function.
0: Dedicated wiring STO function unused
bit 7-1 :
Not used. Set to "0".
bit 0 : omrffon OMR-FF control enabled
0: Disable  1: Enable
【#2314】 SV114 SSF9 Servo function 9
Select the servo functions.
A function is assigned to each bit.
Set this in hexadecimal format.
bit F-9 :
Not used. Set to "0".
bit 8 : nohis History of communication error alarm between NC and DRV (34, 36, 38, 39)
Set "1" for C70.
0: Enable
bit 7 : cse Command speed monitoring function
0: Normal setting
bit 6-0 :
Not used. Set to "0".
278
1: Start
1: Disable
1: Enable
omrffon
sto
ssc
1: Dedicated wiring STO function used
cse
nohis

Advertisement

Table of Contents
loading

Table of Contents