Mitsubishi Electric C70 Setup Manual page 201

Hide thumbs Also See for C70:
Table of Contents

Advertisement

MITSUBISHI CNC
Appendix 1 Explanation of Parameters
【#1071(PR)】 JOG_D JOG activation signal device name
Select the device to input JOG activation signal(+/-).
0: X device
1 or 2: M device
Set the parameters "#1066 JOG_HP" and "#1067 JOG_HN" according to this device specification
parameter.
---Setting range---
0 to 2
【#1072】 chop_ax Chopping axis
Select the chopping axis.
0: Non-chopping axis
1: Chopping axis
【#1073】 I_Absm Initial absolute setting
Select the mode (absolute or incremental) at turning ON the power or reset.
0: Incremental setting
1: Absolute setting
【#1074】 l_Sync Initial synchronous feed
Select the feedrate mode at turning ON the power or reset.
0: Asynchronous feed (feed per minute)
1: Synchronous feed (feed per revolution)
【#1075】 I_G00 Initial G00
Select the linear command mode at turning ON the power or reset.
0: Linear interpolation (G01 command state)
1: Positioning (G00 command state)
【#1076】 Abslnc ABS/INC address (for L system only)
Select the command method for the absolute and incremental commands.
0: Use G command for the absolute and incremental commands.
1: Use axis name for the absolute and incremental commands.
(The axis name in "#1013 axname" will be the absolute command, "#1014 incax" will be the
When "1" is selected, using two axis names, one each for the absolute and incremental commands,
allows to issue the absolute and incremental commands appropriately to an axis.
【#1077】 radius Incremental command for diameter specification axis
Select whether the incremental command of the diameter specification axis ("#1019 dia" is set to "1")
uses the diameter value or radius value.
0: Diameter value
1: Radius value
【#1078】 Decpt2 Decimal point type 2
Select the increment of position commands that do not have a decimal point.
0: Minimum input command unit (follows "#1015 cunit")
1: 1mm (or 1inch) unit (For the dwell time, 1s unit is used.)
【#1079】 F1digt Validate F1 digit
Select the F command method.
0: Direct numerical command (command feedrate during feed per minute or rotation)
1: 1-digit code command (feedrate set with "#1185 spd_F1" to "#1189 spd_F5")
【#1080】 Dril_Z Specify boring axis (for M system only)
Select a fixed cycle hole drilling axis.
0: Use an axis vertical to the selected plane as hole drilling axis.
1: Use the Z axis as the hole drilling axis regardless of the selected plane.
184
incremental command.)

Advertisement

Table of Contents
loading