6 Setting Machine Parameters

6.4.2 Setting Parameters Related to the Hardware Connection

The following shows the minimum required parameters to set up the door interlock II , manual pulse generator , and dual
signal module.

6.4.2.1 Setting the Door Interlock II

When using the door interlock II, set the following parameters.
#1155 DOOR_m: Set a fixed device No. (X device No.) to input the door interlock II signal.
Using this device can realize the same operation as the door open II signal input, without passing through the
PLC.
"000" can not be used as a fixed device No.
When not using the fixed device No, set this to "100".
#1156 DOOR_s: Set the same value as #1155.

6.4.2.2 Setting the Manual Pulse Generator

Set one of the following parameters which is suitable for your manual pulse generator.
- 5V manual pulse generator (UFO-01-2Z9) : #1240 set12/bit0 = 1 (100 pulse/rev)
-12V manual pulse generator (HD60) : #1240 set12/bit0 = 0 ( 25 pulse/rev)
Use G10210/R10 to G10212/R12 to confirm the pulse input from the manual pulse generator.
1st to 3rd handle pulse counter values are output to R10 to R12.
When the pulse input is not confirmed, check the connection or sequence program.

6.4.2.3 Setting the Dual Signal Module

When using the dual signal module, set the following parameters.
#21125 SSU_num: Enter the number of dual signal modules to install.
#21143 to #21145 SSU_Dev1 to Dev3:
Set the head device Nos. to which the dual signal modules, station No. 0 to 2, are installed.
Make sure that the dual signal module I/O assignment in the PC parameters matches the parameter
settings "#21143 SSU_Dev1" to "#21145 SSU_Dev3".
(Note)
For details, refer to "Safety Observation Specification Manual"(BNP-C3059-001N).

6.5 Setting CNC Axis Parameters

Refer to "Appendix 1. Explanation of Parameters" to set parameters according to the machine's specifications.

6.6 Setting CNC Servo Parameters

Refer to "Appendix 1. Explanation of Parameters" and each servo drive unit's manual to set parameters according to the
machine's specifications and servo drive system.

6.7 Setting CNC Spindle Parameters

Refer to "Appendix 1. Explanation of Parameters" and each spindle drive unit's manual to set parameters according to
the machine's specifications and spindle drive system.