【#1258(PR)】 set30
bit0: Skip I/F switch
Select A or B contact for the skip interface.
0: A contact (Skip operation starts at rising edge of a signal)
1: B contact (Skip operation starts at falling edge of a signal)
(Note) This parameter is not applied to PLC skip.
bit1: Enable Position check excessive detection alarm at power ON
Select the alarm to be output when the machine position at the power OFF/ON is bigger than a value
set in "#2051 check".
0: Z70 0006(Abs posn error) will be output.
1: Z70 0007(position check excessive detection at power ON) will be output.
bit7 : PLC axis buffering mode action changeover
Select the action of rotary axis when issuing an absolute value command to the PLC axis in buffering
mode.
0 : Shift as much as the incremental amount calculated by subtracting current value from
1 : When short-cut is disabled, follow the sign of the command value. When short-cut is enabled,
【#1270(PR)】 ext06
bit5: Coordinate rotation angle without command
Select the operation when there is no rotation angle command R for the L system coordinate
rotation.
0: Use the previously commanded value (modal value). If the command is the first issued
1: Use the set value in "#8081 Gcode Rotat".
bit7: Handle C axis coordinate during cylindrical interpolation
Specify whether the rotary axis coordinate before the cylindrical interpolation start command is
issued is kept during the cylindrical interpolation or not.
0: Do not keep
1: Keep
【#1273(PR)】 ext09
bit0 : Arcsine ASIN calculation result range changeover
Select the notation system for operation result of ASIN.
0: Do not switch minus figures to positive figures. (-90° to 90°)
1: Switch minus figures to positive figures. (270° to 90°)
【#1277(PR)】 ext13
bit0: Tool life management II count type 2
Select how and when the mount or use count is incremented in tool life management II.
0: Type 1 (Default)
1: Type 2
command value.
take a short-cut to the commanded position.
command, the rotation angle will be 0°.
Increment the count each time a spindle tool is used for cutting.
Increment the count by one for a tool that is used or mounted in one program. This incrementing
is done at resetting.
Appendix 1.3 Base Specifications Parameters
C70 Setup Manual