3.1.3 Setting Multi-CPU Parameters

(1) Double-click [Parameter]--->[PLC parameter] in the project list. "Q parameter setting" dialog box appears. In the "Q
parameter setting" dialog box, click "Multiple CPU settings".
(2) In "No. of PLC" in the "Multiple CPU settings" dialog box, set the total number of CPU modules mounted on the
base. For example, if one PLC CPU and one CNC CPU are mounted, the number will be "2".
(3) In the "I/O sharing when using Multiple CPUs" field, check the check box of "All CPUs can read all inputs". On the
"Multiple CPU high speed transmission area setting" tab, set "3" to each CPU's "Points (K)", and click "End".
C70 Setup Manual
3.1 GX Works2
61