<135th, 136th word: Log information area>
Token monitoring time-out count:
Indicates the accumulated count of time-out detections for token monitoring time-out time.
<145th, 146th word: Log information area>
Total operating time:
Indicates the total operation time.
<147th, 148th word: Log information area>
Frame wait status count:
Indicates the accumulated count that frame wait status has become.
<149th, 150th word: Log information area>
Participation count:
Indicates the accumulated count of local node participation.
<151st, 152nd word: Log information area>
Self-release count:
Indicates the accumulated count of self release (when token holding time for local node up is
generated 3 consecutive times).
<153rd, 154th word: Log information area>
Release-by-skip count:
Indicates the accumulated count of release by skip (local node address token is pulled out 3
consecutive times).
<155th, 156th word: Log information area>
Other node release count:
Indicates the accumulated count of detections of other node releases.
<169th to 184th word: Log information area>
Participation node list:
Indicates the token participation status at the other node in bits.
0: Release / 1: Participation
bit15
169th word
Node 15
170th word
Node 31
---Setting range---
Within the number of device points set in the PC parameter's device setting.
bit0
Node 1
Node 16
C70 Setup Manual
Appendix 1.8 FL-net Parameters