【#29024(PR)】 Cyclic Data:Area1 Other Node Area Module side Buffer off.
Cyclic data: Area1 Other node area Module side buffer offset
Set the word count of the data used for reading the other node data in cyclic data area1 (bit area).
The standard setting is "0".
(Note) An error will occur when the buffer offset value exceeds "512" after the transfer size is added.
---Setting range---
0 to 512
【#29025(PR)】 Cyclic Data:Area1 Other Node Area PLC side Device
Cyclic data: Area1 Other node area CPU side device
Set the internal device used for reading the other node data in cyclic data area 1 (bit area).
---Setting range---
Within the number of device points set in the PC parameter's device setting.
【#29026(PR)】 Cyclic Data:Area1 Other Node Area Module side Transfer Cont.
Cyclic data: Area1 Other node area Module side transfer word count
Set the word count of the data used for reading the other node data in cyclic data area 1 (bit area).
The standard setting is "512".
(Note) An error will occur when the buffer offset value exceeds "512" after the transfer size is added.
---Setting range---
1 to 512
【#29027(PR)】 Cyclic Data:Area1 Other Node Area Module side Buffer off.
Cyclic data: Area1 Other node area Module side buffer offset
Set the head offset of the buffer used for reading the other node data in cyclic data area 1 (bit area).
The standard setting is "0".
(Note) An error will occur when the buffer offset value exceeds "512" after the transfer size is added.
---Setting range---
0 to 512
【#29028(PR)】 Cyclic Data:Area1 Other Node Area PLC side Device
Cyclic data: Area1 Other node area CPU side device
Set the internal device used for reading the other node data in cyclic data area 1 (bit area).
---Setting range---
Within the number of device points set in the PC parameter's device setting.
【#29029(PR)】 Cyclic Data:Area2 Local Node Area Module side Transfer Cont.
Cyclic data: Area2 Local node area Module side transfer word count
Set the word count of the data which is transferred by the local node to cyclic data area 2 (word
area).
The standard setting is "8192".
(Note) An error will occur when the value buffer offset value exceeds "8192" after the transfer size is
---Setting range---
1 to 8192
added.
C70 Setup Manual
Appendix 1.8 FL-net Parameters