【#7252】 G[06] Type
Set the macro call out type.
0: M98 P △△△△ ; and equivalent value call
1: G65 P △△△△ ; and equivalent value call
2: G66 P △△△△ ; and equivalent value call
3: G66.1 P △△△△ ; and equivalent value call
others: M98 P △△△△ ; and equivalent value call
【#7253】 G[06] Program No.
Set the No. of the program to be called out.
---Setting range---
1 to 99999999
【#7261】 G[07] Code
Set the G code to be used when calling the macro with a G command.
Do not set a G code used in the system.
---Setting range---
1 to 999
【#7262】 G[07] Type
Set the macro call out type.
0: M98 P △△△△ ; and equivalent value call
1: G65 P △△△△ ; and equivalent value call
2: G66 P △△△△ ; and equivalent value call
3: G66.1 P △△△△ ; and equivalent value call
others: M98 P △△△△ ; and equivalent value call
【#7263】 G[07] Program No.
Set the No. of the program to be called out.
---Setting range---
1 to 99999999
【#7271】 G[08] Code
Set the G code to be used when calling the macro with a G command.
Do not set a G code used in the system.
---Setting range---
1 to 999
【#7272】 G[08] Type
Set the macro call out type.
0: M98 P △△△△ ; and equivalent value call
1: G65 P △△△△ ; and equivalent value call
2: G66 P △△△△ ; and equivalent value call
3: G66.1 P △△△△ ; and equivalent value call
others: M98 P △△△△ ; and equivalent value call
【#7273】 G[08] Program No.
Set the No. of the program to be called out.
---Setting range---
1 to 99999999