【#1357(PR)】 mchkt1 Contactor operation check tolerance time 1
Set the time between outputting the contactor shutoff output 1 and establishing an emergency stop
in case the contactor does not move.
When set to "0", this function will be invalidated.
---Setting range---
0 to 30000(ms)
【#1361(PR)】 aux_acc Auxiliary axis constant inclination
Select the acceleration/deceleration type of the auxiliary axis in PLC axis indexing.
0 : Acceleration and deceleration with constant time
1 : Acceleration and deceleration with a constant angle of inclination
【#1368(PR)】 SfAlmRstD Safety observation alarm reset inputting device
Turn ON the X device set in this parameter to cancel the safety observation alarm by resetting.
Select other device than reset button to avoid mistakenly canceling the safety observation alarm
which may happen by only pressing the reset button if the same device No. as the X device assigned
to the reset button is set in this parameter.
When set to "0", the safety observation alarm will not be canceled with the reset button. (X0 cannot
be used)
---Setting range---
0000 to 01FF (HEX)
【#1383】 Alm1DBord Alarm displaying threshold (1D)
Set threshold for turning ON the detector alarm (1D).
The threshold is "2" when "0" is set.
---Setting range---
0 to 4000
【#1384】 Alm1FBord Alarm displaying threshold (1F)
Set threshold for turning ON the detector alarm (1F).
The threshold is "2" when "0" is set.
---Setting range---
0 to 4000
【#1385】 Alm2DBord Alarm displaying threshold (2D)
Set threshold for turning ON the detector alarm (2D).
The threshold is "2" when "0" is set.
---Setting range---
0 to 4000
【#1386】 Alm2FBord Alarm displaying threshold (2F)
Set threshold for turning ON the detector alarm (2F).
The threshold is "2" when "0" is set.
---Setting range---
0 to 4000
【#1387】 Alm41Bord Alarm displaying threshold (41)
Set threshold for turning ON the detector alarm (41).
The threshold is "1" when "0" is set.
---Setting range---
0 to 3