Air-conditioner Control System Optional Parts
Mounting attachment B type for use with AG-150A
PAC-YG81TB
Installation Manual

1 Safety Precautions

• Before installing the Mounting attachment B type, please read the following safety precautions carefully to ensure proper
installation.
• Observe the following precautions to ensure safety.
• The following symbols are used in this manual to indicate the type and severity of potential consequences that may result when
given instructions are not followed exactly as stated.
WARNING
Indicates a risk of death or serious injury.
CAUTION
Indicates a risk of injury or damage to the product.
• After the completion of installation, perform a test run to confirm proper operation.
• Retain this manual for future reference. When the unit is reinstalled or repaired, make this manual available to those who provide
these services. Make sure that the manual is passed on to any future air condition system users.
Only a dealer or qualified technician should replace
the unit.
Improper replacement by an unqualified person may result
in electric shock or fire.
The Mounting attachment B type should be installed
on a surface that is strong enough to support the
weight of the unit.
If the Mounting attachment B type is installed on a surface
that lacks the strength to support it, it may fall and cause
injury.
Do not attempt to modify or repair the Mounting
attachment B type.
Modification or improper repair may result in electric shock
or fire. Consult your dealer when repairs are necessary.
Do not install the Mounting attachment B type where
there is a risk of leaking flammable gas.
If the leaked gas accumulates around the Electric Box, it
may ignite and cause an explosion.
Do not use the Mounting attachment B type in an
environment that has high concentrations of oil,
steam, or sulfuric gas.
These substances may have adverse effects on the
performance of the Mounting attachment B type or
damage its parts.
Seal the wire access holes with putty to prevent dew,
water, and insects from entering to avoid electric
shock.
WARNING
Install the Mounting attachment B type properly
according to the instructions detailed in this
Installation Manual.
Improper installation by an unqualified person may result in
electric shock or fire.
Electric work must be performed by authorized
personnel according to the local regulations and the
instructions detailed in the Installation Manual.
Inadequate circuit capacity or improper installation may
result in electric shock or fire.
Ask your dealer or an authorized technician to move
the Mounting attachment B type.
Improper installation by an unqualified person may result in
electric shock or fire. Consult your dealer or a qualified
technician.
CAUTION
Do not install this Mounting attachment B type in a
place that has the potential for steam, such as a
bathroom or kitchen.
Steam may cause an electric shock or a unit malfunction.
Do not install this Mounting attachment B type where
an acid, alkaline solution, or special chemical spray is
used frequently to avoid electric shock or malfunction.
Keep the cables from coming in direct contact with the
edges of the wire access holes.
If the cables are damaged, they may cause electric shock
or fire.
This Mounting attachment B type is for exclusive use
with the AG-150A and cannot be used with other
devices.
- 1 -
Applicable
Centralized Controller
AG-150A
Model

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric PAC-YG81TB

  • Page 1: Safety Precautions

    AG-150A Model Air-conditioner Control System Optional Parts Mounting attachment B type for use with AG-150A PAC-YG81TB Installation Manual 1 Safety Precautions • Before installing the Mounting attachment B type, please read the following safety precautions carefully to ensure proper installation.
  • Page 2: Parts List

    Use screws that are suitable for the wall type. The weight of the AG-150A including the Mounting attachment B type (PAC-YG81TB) is 2.7 kg (6.0 lbs). Use screws with the head size of between 7.0 and 8.8 mm (5/16 and 6/16 in).
  • Page 3: Selecting An Installation Site

    The cable can be routed either from the top or the bottom. 1. To route the cable from the top (1) Cut out the knockout hole on the Mounting attachment B type (PAC-YG81TB) at the top with a nipper for the cable (the thin part of the plastic).
  • Page 4 (3) Install the Mounting attachment B type (PAC-YG81TB) with NOTE the six mounting screws (field-supplied). Use screws that are suitable for the wall type. Install the Mounting attachment B type (PAC-YG81TB) so that the arrow ( UP) on the back of it points up.
  • Page 5 (6) Connect the cable to the AG-150A. Refer to the AG-150A Installation Manual for details. CAUTION * When routing the cable from the top of the controller, let the cable hang down below the connector before connecting it to the terminal block or connector as shown in the figure below to prevent water from running down the cable and cause electric shock or fire.
  • Page 6 (9) Install the AG-150A with the four screws that are supplied. If the LAN link-up cable is used, place it inside the Mounting attachment B type. (10) Attach the cover on the AG-150A. - 6 -...
  • Page 7 2. To route the cable from the bottom (1) Cut out the knockout hole on the Mounting attachment B type (PAC-YG81TB) at the bottom with a nipper for the cable. NOTE Install the Mounting attachment B type (PAC-YG81TB) so that the arrow ( UP) on the back of it points up.
  • Page 8 (4) Push the cable through the knockout hole. (5) Remove AG-150A surface cover. Insert a flat-tip screwdriver in the holes indicated and move the handle up to remove the cover. (6) Connect the cable to the AG-150A. Refer to the AG-150A Installation Manual for details. Back of controller M-NET Shield...
  • Page 9 (7) If the AG-150A is not always connected to the LAN, connect the supplied LAN link-up cable to the LAN connector. (* If the AG-150A is always connected to the LAN, connect the LAN cable (field supplied) via a HUB and the LAN link-up cable is not required.) LAN link-up cable (supplied) (8) Install the AG-150A with the four screws that are supplied.
  • Page 10: Access Panel

    7 Access panel There is a maintenance access panel at the bottom of the Mounting attachment B type. The maintenance access panel is used for maintenance purpose when the AG-150A is not always connected to the LAN. To open the maintenance access panel (1) Unscrew the four screws on the panel with a Phillips driver.
  • Page 12 Please be sure to put the contact address/telephone number on this manual before handing it to the customer. HEAD OFFICE: TOKYO BLDG. , 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN Authorized representative in EU: MITSUBISHI ELECTRIC EUROPE B.V. HARMAN HOUSE, 1 GEORGE STREET, UXBRIDGE, MIDDLESEX UB8 1QQ, U.K. WT05422X02...

Table of Contents