MITSUBISHI CNC
Appendix 1 Explanation of Parameters
【#13194】 SP194 LMN Base speed for load meter standard output (High-speed coil)
Set the base speed of the standard output to be displayed as 100% in load meter.
When "0" is set, the base speed of the short-time rated output will be applied.
It is not available for MDS-DJ-SP Series.
---Setting range---
0 to 32767 (r/min)
【#13195】 SP195 LMRL Change magnification for load meter standard output (Low-speed
coil)
Set the standard output to be displayed as 100% in load meter using the short-time rated output
ratio.
To display the continuous rated output as 100%, set as follows.
Continuous rated output/Short-time rated output × 100
When "0" is set, normal display will be applied.
It is not available for MDS-DJ-SP Series.
---Setting range---
0 to 100 (%)
【#13196】 SP196 LMNL Base speed for load meter standard output (Low-speed coil)
Set the base speed of the standard output to be displayed as 100% in load meter.
When "0" is set, the base speed of the short-time rated output will be applied.
It is not available for MDS-DJ-SP Series.
---Setting range---
0 to 32767 (r/min)
【#13197】 SP197
Not used. Set to "0".
【#13198】 SP198
Not used. Set to "0".
【#13199】 SP199
Not used. Set to "0".
【#13200】 SP200
Not used. Set to "0".
【#13201】 SP201
Not used. Set to "0".
【#13202】 SP202
Not used. Set to "0".
【#13203】 SP203
Not used. Set to "0".
【#13204】 SP204
Not used. Set to "0".
【#13205】 SP205
Not used. Set to "0".
【#13206】 SP206
Not used. Set to "0".