M01 Playback not possible 0117
Details
The playback switch was turned ON during editing.
Remedy
- Cancel the editing by pressing the input or previous screen key before turning ON the playback
switch.
M01 Turn stop in normal line cntrl 0118
Details
The turning angle at the block joint exceeded the limit during normal line control.
In normal line control type I:
"#1523 C_feed (Normal line control axis turning speed)" has not been set.
In normal line control type II:
When turning in the inside of the arc, the set value for "#8041 C-rot. R" is larger than the arc radius.
Remedy
- Correct the program.
- Correct the "#1523 C_feed (Normal line control axis turning speed)" setting.
- Correct the "#8041 C rot. R" setting.
M01 Illegal operation mode for synchronous correction mode 0120
Details
While synchronization correction mode is ON, operation mode is illegally set to a mode other than
handle or manual arbitrary feed.
Remedy
- Select the handle or manual arbitrary feed mode.
- Cancel the synchronous correction mode.
M01 No synchronous control option 0121
Details
A value was entered to the synchronous control operation method register when multi-secondary-axis
synchronous control and synchronous control options are not provided.
Remedy
- Set "0" for the synchronous control operation method register.
M01 X/Z axes simultaneous prohibit 0124
Details
The basic axis corresponding to the inclined axis was started simultaneously in the manual mode while
the inclined axis control was valid.
Remedy
- Turn the inclined axis and basic axis start OFF for both axes. (This is also applied for manual/
automatic simultaneous start.)
- Disable the basic axis compensation, or command it to axes one by one.
M01 Program restart machine lock 0126
Details
Machine lock was applied on the return axis being manually returned to the restart position.
Remedy
- Cancel the machine lock and resume the operation.
M01 Zero point return interruption 0131
Details
Automatic operation was started after a zero point return interruption.
Remedy
- Reset and start the automatic operation.
C70 Setup Manual
Appendix 2.1 Operation Errors (M)
425