【#1218】 aux02
bit3: Parameter input/output format
Select the parameter input/output format.
0: Type I
1: Type II (related to "#1218 aux02/bit5")
bit4: External workpiece coordinate offset tool number selection
Select the R register that contains the tool number used for automatic calculation when measuring
the coordinate offset of an external workpiece.
0: Follow the setting of "#1130 set_t".
1: Use the tool number indicated by user PLC.
bit5: Parameter I/O II spindle specification address
Select the spindle specification address of parameter I/O type II.
0: C
1: T
This parameter is also applied to the spindle specification address for input and verification.
(Note) This parameter is valid only for parameter I/O type II (when "#1218 aux02/bit3" is set to "1").
bit6: Set No. valid when program input
Select which program No. is applied when inputting programs in "#1 MAIN PROGRAM" on Data I/O
screen.
0: The No. in the input data
1: The No. set in the data setting area
bit7: Input by program overwrite
Select the operation when the program to be input in "#1 MAIN PROGRAM" on Data I/O screen, has
already been registered.
0: An operation error (E65) occurs.
1: Input by overwrite.
Appendix 1.3 Base Specifications Parameters