【#21126 to 21141(PR)】 SODR_1 to SODR_16 Speed monitor input device door 1 to 16
Set the device Nos. to which the door sensor signal is input to inform the open/close states of the
doors 1 to 16 during speed monitoring.
Setting to "0" means that the door is always open.
Therefore, "X0" cannot be used as the input device of door signals.
(Note)These settings will be ignored when #21163(InvalidDoorSgnl) is set to "1".
---Setting range---
0000 to 01FF (hexadecimal)
【#21142(PR)】 SSU_delay Dual-signal comparison tolerance time
Set the time in which mismatches of input/output signals to/from PLC and NC in the dual signal
module are allowed.
When set to "0", the signal comparison tolerance time is 100ms.
---Setting range---
0 to 50(100ms)
【#21143 to 21145(PR)】 SSU_Dev1 to SSU_Dev3 Dual signal module device
Set the head device Nos. to which the dual signal modules, station No. 0 to 2, are installed.
This I/O assignments need to correspond to those in GX Works2 / GX Developer.
The same device No. cannot be shared among different modules.
---Setting range---
0000 to 01FF (hexadecimal)