Appendix 1 Explanation of Parameters
【#21049】 SPname
Select the spindle No. to be selected in G43.1 modal for each part system.
0 : 1st spindle
1 : 1st spindle
2 : 2nd spindle
3 : 3rd spindle
4 : 4th spindle
5 : 5th spindle
6 : 6th spindle
7 : 7th spindle
【#21050】 plcdwlskp G04 skip condition
Set the PLC skip signal for suspending the G04 (dwell) command.
The PLC skip signal 1 to 32 is corresponded to bit0 to 31.
---Setting range---
00000000 to FFFFFFFF(HEX)
【#21051】 plcskip1 G31.1 skip condition
Designate the PLC skip signal in multi-step skip G31.1.
The PLC skip signal 1 to 32 is corresponded to bit0 to 31.
---Setting range---
00000000 to FFFFFFFF(HEX)
【#21052】 plcskip2 G31.2 skip condition
Designate the PLC skip signal in multi-step skip G31.2.
The PLC skip signal 1 to 32 is corresponded to bit0 to 31.
---Setting range---
00000000 to FFFFFFFF(HEX)
【#21053】 plcskip3 G31.3 skip condition
Designate the PLC skip signal in multi-step skip G31.3.
The PLC skip signal 1 to 32 is corresponded to bit0 to 31.
---Setting range---
00000000 to FFFFFFFF(HEX)