Mitsubishi Electric C70 Setup Manual page 418

Hide thumbs Also See for C70:
Table of Contents

Advertisement

【#12873】 PSW02-1 PSW2 area setting 1
Set "PSW2 area setting" 1 and 2 to specify the area where the position switch 2 will turn ON when
the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position
switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12874】 PSW02-2 PSW2 area setting 2
Set "PSW2 area setting" 1 and 2 to specify the area where the position switch 2 will turn ON when
the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position
switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12875】 PSW03-1 PSW3 area setting 1
Set "PSW3 area setting" 1 and 2 to specify the area where the position switch 3 will turn ON when
the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position
switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12876】 PSW03-2 PSW3 area setting 2
Set "PSW3 area setting" 1 and 2 to specify the area where the position switch 3 will turn ON when
the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position
switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12877】 PSW04-1 PSW4 area setting 1
Set "PSW4 area setting" 1 and 2 to specify the area where the position switch 4 will turn ON when
the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position
switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12878】 PSW04-2 PSW4 area setting 2
Set "PSW4 area setting" 1 and 2 to specify the area where the position switch 4 will turn ON when
the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position
switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
Appendix 1.14 PLC Axis Indexing Parameters
C70 Setup Manual
401

Advertisement

Table of Contents
loading