【#1203】 TmirS1 Select turrets as facing turrets with T command (for L system only)
Select the turrets, which correspond to the tool Nos. 1 to 32, as facing turrets for T code mirror
image.
---Setting range---
0 to FFFFFFFF
【#1204】 TmirS2 Select turrets as facing turrets with T command (for L system only)
Select the turrets, which correspond to the tool Nos. 33 to 64, as facing turrets for T code mirror
image.
---Setting range---
0 to FFFFFFFF
【#1205】 G0bdcc Acceleration and deceleration before G0 interpolation
0: Post-interpolation acceleration/deceleration is applied to G00.
1: Pre-interpolation acceleration/deceleration is applied to G00 even in the high accuracy control
(Note) Set "0" for the 2nd part system and the following.
【#1206】 G1bF Maximum speed
Set a cutting feedrate when applying pre-interpolation acceleration/deceleration.
---Setting range---
1 to 1000000 (mm/min)
【#1207】 G1btL Time constant
Set a cutting feed time constant when applying pre-interpolation acceleration/deceleration.
Speed
G1bF
---Setting range---
1 to 5000 (ms)
【#1208】 RCK Arc radius error compensation factor
Set a coefficient for arc radius error compensation.
An arc radius error compensation amount can be increased or decreased between -60.0 and
+20.0%.
---Setting range---
-60.0 to +20.0 (%)
【#1209】 cirdcc Arc deceleration speed
Set the deceleration speed at the arc entrance or exit.
---Setting range---
1 to 1000000 (mm/min)
mode.
G1btL
Appendix 1.3 Base Specifications Parameters