Mitsubishi Electric C70 Setup Manual page 292

Hide thumbs Also See for C70:
Table of Contents

Advertisement

【#2288】 SV088 FHz5 Notch filter frequency 5
Set the vibration frequency to suppress when machine vibration occurs.
(Normally, do not set 80 or less.)
Set to "0" when not using.
Related parameters: SV083/bit7-5, SV115
---Setting range---
0 to 2250 (Hz)
【#2289】 SV089
Not used. Set to "0".
【#2290】 SV090
Not used. Set to "0".
【#2291】 SV091 LMC4G Lost motion compensation 4 gain
Use this with LMC compensation type 3. As the delay in path tracking is monitored and
compensated, the delay in path tracking will be minimized even if machine friction amount changes
by aging. Use the lost motion compensation amount (SV016) * 5 (10% of the dynamic friction torque)
as the target. The higher the setting value is, the more accurate the quadrant change be; however,
the more likely vibrations occur.
---Setting range---
0 to 20000 (Stall current 0.01%)
【#2292】 SV092
Not used. Set to "0".
【#2293】 SV093
Not used. Set to "0".
【#2294】 SV094 MPV Magnetic pole position error detection speed
The magnetic pole position detection function monitors the command speed and motor speed at the
position command stop and detects the magnetic pole position error alarm (3E) if any. Set the error
detection level for the command speed and motor speed at the position command stop.
Be aware when setting the parameter as the setting units for general motors and linear motors are
different.
<<For general motor>>
When the command speed error detection level is set to "0", the magnetic pole position error (3E) is
detected at 10r/min.
Set "10" as standard.
This detects the magnetic pole position error (3E) when the motor rotation speed is 100r/min and
more.
<<For linear motor>>
When the command motor speed level is set to "0", the magnetic pole position error (3E) is detected
at 1mm/s.
Set "10" as standard.
This detects the magnetic pole position error (3E) when the motor speed is 10mm/s and more.
---Setting range---
0 to 31999
<<For general motor>>
Ten-thousands digit, Thousands digit ----------- Command speed error detection level (10r/min)
Hundreds digit, Tens digit, Ones digit ----------- Motor speed error detection level (10r/min)
<<For linear motor>>
Ten-thousands digit, Thousands digit ----------- Command speed error detection speed level (1mm/
s)
Hundreds digit, Tens digit, Ones digit ----------- Motor speed error detection level (1mm/s)
C70 Setup Manual
Appendix 1.5 Servo Parameters
275

Advertisement