【#1521】 C_min Minimum turning angle
Set the minimum turning angle of the normal line control axis at the block joint during normal line
control.
---Setting range---
0.000 to 360.000 (°)
【#1522(PR)】 C_axis Normal line control axis
Set the number of the axis for normal line control.
Set a rotary axis No.
---Setting range---
1 to 8
【#1523】 C_feed Normal line control axis turning speed
Set the turning speed of the normal line control axis at the block joint during normal line control.
Set a value that does not exceed the normal line control axis' clamp speed ("#2002 clamp").
This is valid with normal line control type I.
---Setting range---
0 to 1000000 (°/min)
【#1524】 C_type Normal line control type
Select the normal line control type.
0: Normal line control type I
1: Normal line control type II
【#1533】 millPax Pole coordinate linear axis name
Set the linear axis name used for pole coordinate interpolation.
---Setting range---
Axis name such as X, Y or Z
【#1535】 C_leng Minimum turning movement amount
Set the minimum turning movement amount of the normal line control axis at the block joint during
normal line control.
---Setting range---
0.000 to 99999.999 (mm)
【#1567】 mill_err Error between linear axis and rotary axis center
Set the error between the linear axis and the rotary axis center (the error being deviation from the
rotary axis center to the vertical direction of linear axis.)
Set the error amount by the radius value.
---Setting range---
-9999.999 to 9999.999 (mm)
【#1568】 SfiltG1 G01 soft acceleration/deceleration filter
Set the filter time constant for smoothly changing the acceleration rate for the cutting feed
acceleration/deceleration in pre-interpolation acceleration/deceleration.
---Setting range---
0 to 200 (ms)
【#1569】 SfiltG0 G00 soft acceleration/deceleration filter
Set the filter time constant for smoothly changing the acceleration rate for the rapid traverse
acceleration/deceleration in pre-interpolation acceleration/deceleration.
---Setting range---
0 to 200 (ms)