6.8 Servo Simplified Adjustment

6.8.1 First Measure Against Vibration

Vibration may occur when CNC is turned ON after setting parameters.
Setting the filter can reduce the vibration.
(1) Select [ALARM/DIAGN] --> [SERVO] on the CNC monitor screen.
(2) Touch the page scroll key and confirm the displayed value of the "AFLT FREQUENCY".
(Note)
(3) Display [SERVO PARAM] screen from [TOOL PARAM] and input the "AFLT FREQUENCY" value, which is
confirmed in the step (2), to "#2238 SV038 FHz1 (Notch filter frequency 1)".
(Note)
This screen display is for when NC parameters have default value.
This screen display is for when NC parameters have default value.