CHAPTER 4 APPENDICES
Appendix 4. Warning Messages
Message
The MANUAL FEEDRATE
feedrate zero
switch on the machine operation
panel is set to "0" when the
machine is in the jog mode or
automatic dry run mode.
The spindle stopped during the
synchronous feed command.
An interlock signal that locks the
interlock
start of the block has been input.
An interlock signal that locks the
start interlock
start of the cutting block has
been input.
The restart switch was turned
ON
ON before the restart search
was completed, and the manual
mode was selected.
Restarting was attempted before
posn not
the program restart search was
searched
completed.
Automatic start is not possible
posn not
because the axis has not
returned
returned to the program restart
position.
Starting was attempted without
setting an MDI in the MDI mode.
Operation was attempted during
search
a program search.
Starting was attempted during a
mode
program check or program
check mode.
Starting was attempted during
correction
buffer correction.
Starting was attempted during
the reset process.
search engine
Details
• Set the switch to a value other
than "0" to release the error.
• If the switch is set to a value other
than "0", check for a short circuit
in the signal wire.
• Check the sequence program.
• Rotate the spindle.
If the workpiece is not being cut,
start dry run.
• Check for a broken wire in the
spindle encoder cable.
• Check the connections for the
spindle encoder connectors.
• Check the spindle encoder pulse.
• Check the sequence program.
Restart the program while
simultaneously canceling the
signal.
• Check the sequence program.
Restart the program while
simultaneously canceling the
signal.
• Search the block to be restarted.
• Turn OFF the restart switch.
• Restart after the program restart
search is completed.
• Manually return the axis to the
restart position, or turn ON the
Auto restart valid parameter and
automatically start.
• Restart after setting an MDI.
• Wait for the program search to
complete, or restart after
canceling the program search by
resetting.
• Wait for the program check to
complete, or restart after
canceling the program check by
resetting.
• Cancel the buffer correction by
resetting or screen changeover.
Complete the buffer correction by
pressing the (INPUT CALC) key.
• Restart after the reset process is
completed.
IV – 59