Mitsubishi Electric MELDAS 600M Series Instruction Manual page 275

Table of Contents

Advertisement

5.3.3 Carrying out one-shot output
(1) One-shot outputting data "1" to device "X0042".
!
Downloaded from
ManualsNet.com
CHAPTER 1 SCREEN OPERATIONS
1)
Press the menu key
.
1-shot output
2)
Set the device and data,
press the
key.
INPUT
X0042/1
(Note) Because the input signal (X, etc.) to the PLC is updated at the head of each PLC cycle,
the machine immediately returns to the normal state, even if one-shot type forced
output is carried out.
Caution
Pay close attention to the sequence operation when carrying out forced data setting (forced
output) in the I/F diagnosis screen.
search engine
5. Diagnosis Screens
The one-shot output mode is entered, and the cursor
appears at the one-shot output area.
The input data is overwritten in the one-shot output area,
and is one-shot output. The cursor in the one-shot
output area disappears.
The data of the one-shot output device is displayed in
order in the selected area.
The one-shot output mode is canceled by pressing the
key.
I – 260

Advertisement

Table of Contents
loading

Table of Contents